Skip to content   Skip to footer navigation 

Thermann X Hybrid 300 review

300L capacity. Priced at $4580.

  • Thermann X Hybrid 300 carousel image
Image thumbnail 0
Price View more details.

Prices are based on what we found on retailer or manufacturer websites in February 2024. Manufacturers often sell direct to installers, so for some models the price isn't publicly available.

$4580
Model type View more details.

Integrated models are all-in-one units with the heat pump compressor at the top of the tank. Split systems have separate compressor and tank components (much like a split system air conditioner), which can allow the tank to be installed indoors.

Integrated
STC Zone 5 View more details.

Small-scale Technology Certificates (STCs) are a Federal financial incentive to encourage the installation of solar and heat pump water heaters. Australia is divided into climate zones, and this number refers to the base number of STCs you can get for this model in Zone 5. The actual number will depend on the year of installation; it reduces each year until the scheme ends in 2030.

30
STC Zone 3 View more details.

Small-scale Technology Certificates (STCs) are a Federal financial incentive to encourage the installation of solar and heat pump water heaters. Australia is divided into climate zones, and this number refers to the base number of STCs you can get for this model in Zone 3. The actual number will depend on the year of installation; it reduces each year until the scheme ends in 2030.

28
STC Zone 2 View more details.

Small-scale Technology Certificates (STCs) are a Federal financial incentive to encourage the installation of solar and heat pump water heaters. Australia is divided into climate zones, and this number refers to the base number of STCs you can get for this model in Zone 2. The actual number will depend on the year of installation; it reduces each year until the scheme ends in 2030.

25
STC Zone 4 View more details.

Small-scale Technology Certificates (STCs) are a Federal financial incentive to encourage the installation of solar and heat pump water heaters. Australia is divided into climate zones, and this number refers to the base number of STCs you can get for this model in Zone 4. The actual number will depend on the year of installation; it reduces each year until the scheme ends in 2030.

31
STC Zone 1 View more details.

Small-scale Technology Certificates (STCs) are a Federal financial incentive to encourage the installation of solar and heat pump water heaters. Australia is divided into climate zones, and this number refers to the base number of STCs you can get for this model in Zone 1. The actual number will depend on the year of installation; it reduces each year until the scheme ends in 2030.

24
Air flow rate (m3/h) View more details.

Where it is declared, this is the air flow rate of the heat pump's compressor in cubic metres per hour.

Not stated
Booster element power consumption (kW) View more details.

The energy used by the booster element, in kilowatts.

1.6
Capacity (L) View more details.

The capacity of the tank, in litres.

300
Company name View more details.

The company associated with the heat pump hot water system. Sometimes this is the same as the brand but not always.

Reece
Cylinder material View more details.

This is generally what the interior of the tank is made from.

Not stated
Heat pump depth (mm) View more details.

The depth of the compressor unit of a split system, in millimetres. Not applicable for integrated models.

N/A
Heat pump height (mm) View more details.

The height of the compressor unit of a split system, in millimetres. Not applicable for integrated models.

N/A
Heat pump width (mm) View more details.

The width of the compressor unit of a split system, in millimetres. Not applicable for integrated models.

N/A
Heat pump weight (kg) View more details.

How heavy the heat pump part of the split type is, measured in kilograms.

N/A
IP rating View more details.

IP ratings refer to the protection rating, usually with the letters IP and two digits. The first digit is the protection against solid particules getting into the product and the second digit is protection against water getting into the product. Where there is an X for the first digit, it means a rating isn't necessary. The higher the number on either digit, the better the protection.

IP24
Maximum delivery (L/hr) View more details.

The maximum amount of hot water the system can deliver in one hour, in litres, unless otherwise described.

Not stated
Maximum horizontal displacement from tank (m) View more details.

In a split system, how far horizontally can the heat pump be from the tank? Listed in metres.

N/A
Maximum vertical displacement from tank (m) View more details.

In a split system, how far vertically can the heat pump be from the tank? Listed in metres.

N/A
Maximum operating pressure temperature relief valve (kPa) View more details.

The maximum operating pressure and temperature relief valve of the heat pump hot water system, in kilopascals. The valve is a safety device that prevents a build-up of pressure due to water expansion as the water heats up.

850
Minimum clearance for side intake (mm) View more details.

The minimum clearance for the intake, or inlet, of the heat pump hot water system, in millimetres.

400
Minimum clearance for side outlet (mm) View more details.

The minimum clearance needed at the outlet, or exhaust of the heat pump hot water system, in millimetres. The exhaust will pump out cold air.

400
Noise level (dbA) View more details.

The noise level of the heat pump hot water system compressor. Compressors can sometimes be noisy and shouldn't be installed too close to neighbouring properties or bedroom windows. 40dBA is a equivalent to a whispered conversation, whereas 60dBA would be an average conversation level.

45 (1m)
Output water temperature (°C) View more details.

The temperature of the hot water delivered from the heat pump hot water system (note that the tank is usually kept at at least 60°C to prevent bacterial growth, but tempered to 50°C from your hot water taps).

61 (65 max)
Rated voltage (V) View more details.

The rated voltage of the heat pump hot water system.

230
Tank width (mm) View more details.

How wide the system tank is, in millimetres.

690
Tank depth (mm) View more details.

How deep the system tank is, in millimetres.

690
Tank height (mm) View more details.

How high the system tank is, in millimetres.

1913
Tank weight when empty (kg) View more details.

How heavy the tank is when empty, in kilograms.

135
Tank weight when full (kg) View more details.

How heavy the system tank is when full, in kilograms.

435
Maximum working ambient temperature (°C) View more details.

The claimed maximum ambient temperature in which the heat pump hot water system will operate.

42
Minimum working ambient temperature (°C) View more details.

The claimed minimum ambient temperature in which the heat pump hot water system will operate.

-5
Website View more details.

The main manufacturer or distributor site for this model.

Not available
Covered under the VEEC scheme View more details.

Whether this model is covered under the Victorian Energy Efficiency Certificates scheme.

Yes
Covered under the NSW ESS View more details.

A registration number here indicates this model is covered under the NSW Energy Savings Scheme (at the time of publication).

ACC0025243
Heat pump power input (kW) View more details.

The power consumption for the heat pump only (i.e. just the compressor, not any booster element), in kilowatts.

0.55
Maximum power consumption (kW) View more details.

The maximum power consumption of the heat pump hot water system (including any booster element), in kilowatts.

0.65
Refrigerant capacity (kg) View more details.

The amount of refrigerant required by the heat pump, in kilograms.

0.85
Refrigerant type View more details.

The refrigerant type used by the heat pump compressor. R290 is propane and R744 is refrigerant grade CO2, both considered reasonably environmentally safe (low global warming potential). R134a is tetrafluoroethane, a hydrofluorocarbon, which has higher global warming potential.

R134a
Seasonal coefficient of performance View more details.

Coefficient of performance (COP) is a measure of the unit's efficiency. The higher the number, the better. It shows how much heating energy output this model delivers per unit of electricity used. Note that the COP is dependent on the ambient temperature of the air, and different manufacturers rate their models at different ambient temperatures, so it's hard to compare COPs between brands and models.

3.58 (climate zone 2)
Watermark certificate View more details.

This is a mandatory national scheme administered by the Australian Building Codes Board for drainage and plumbing products – the certificate number shows that the heat pump hot water system is fit for purpose.

000301
Warranty View more details.

Warranty can be complex with heat pump hot water systems, as they specify at least the storage tank, compressor (heat pump), parts and labour – and sometimes valves. There is little consistency between manufacturers.

Cylinder: 5; Parts and labour: 2
Country of origin View more details.

Country of manufacture, where stated by the manufacturer or retailer. 

Not stated
Booster element View more details.

Whether the heat pump hot water system has a booster element for additional heating (such as when the hot water has been used up, or on very cold days).

Yes
Defrost cycle View more details.

Defrost cycles are essential in cold areas, where icing can occur on the compressor unit.

Yes
Suitable for cold temperatures View more details.

Whether the heat pump hot water system is claimed to be suitable for cold temperatures (subzero conditions).

Yes
Suitable household size View more details.

The household size for which this system is suitable. This is a manufacturer claim. To estimate your household's hot water usage, assume 50L of hot water per person per day, plus 50% for occasional heavy usage days.

3-6 people
Member reviews